How To Extend Ethernet Cable?
https://www.newyorkcables.com/product/rj45-connector-cat6/
Get an Ethernet RJ45 coupler (get a premium quality coupler for the best performance)
Plug the RJ45 Connector on your ethernet cable into the coupler
Plug Ethernet Cable into the other side of the coupler and you’ve just extended your Ethernet Cable
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
Cat6a is the best ethernet network cable for long distances. It comes with a solid core bare copper conductor.
https://www.newyorkcables.com/cat6a-cable-bulk/
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
Cat5e: Basic household applications. Cat6: Medium-scale commercial and high-performance residential applications. Cat6a: All sorts of business, household, and data center applications
https://www.newyorkcables.com/cat6a-cable-bulk/
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
Decide the applications that you will use such as printers, drives, etc, and also decide the number of devices you will be using.  Run ethernet cables bulk to your devices. 
Install a router or switch and connect high quality ethernet cables with it.  Configure the WAN and LAN ports. Your ISP will supply the WAN configuration settings. And LAN ports are configured automatically.
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
UTP (Unshielded twisted pair) is a cable with wires that are twisted together to minimize noise and crosstalk. STP (Shielded twisted pair) is a cable with wires that are twisted together to reduce noise and crosstalk. STP (Shielded Twisted Pair), on the other hand, is a twisted pair cable encased in a foil or mesh shield that protects the line from electromagnetic interference.
https://www.newyorkcables.com/category/cat6-plenum-ethernet-cable/
0 notes
newyorkcablesblog · 3 years ago
Link
0 notes
newyorkcablesblog · 3 years ago
Link
The Cat6 Riser ETL-Listed Ethernet cable comes with a CMR-rated jacket, which makes this cable fit for installation in riser or vertical spaces of the buildings. CMR stands for Communications Multipurpose Cable Riser.
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
Bulk Cat6a Plenum Cable
https://www.newyorkcables.com/category/cat6a-plenum-cable/
0 notes
newyorkcablesblog · 3 years ago
Link
0 notes
newyorkcablesblog · 3 years ago
Link
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
https://www.newyorkcables.com/updates/cat5e-cable-safe-bend-radius-data-transfer-speeds-testing-explained/
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
UL vs ETL certifications: What's the difference?
https://www.newyorkcables.com/
0 notes
newyorkcablesblog · 3 years ago
Video
tumblr
CMP-rated jackets halt fire progression and emit no toxic gases. Designed for installation in Plenum/Horizontal spaces of the building
https://www.newyorkcables.com/category/cat6-bare-copper/
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
Major Advantages of Cat6 Plenum Solid Copper Cable
https://www.newyorkcables.com/category/cat6-bare-copper/
0 notes
newyorkcablesblog · 3 years ago
Text
How to Easily Make Good Cat6 Cable All The Time
Without question, buying Ethernet patch cables from a store is the most convenient and straightforward method of resolving networking issues. Where, however, is the joy in that? Why don't you construct your Cat6 Cable if you're utilizing Cat6 cables?
The procedure is straightforward. All you have to do now is read this post and follow the instructions carefully.
Gather All Equipment
RJ45 connectors, cat6 ethernet cables, cable boots, cable cutters, crimp tool, cable strippers, measuring tape, network tester, and a strong cup of coffee are all needed to build Cat6 cable.
Step 2: Length Measurements
To save cable, you must pay close attention to length considerations. When gauging lengths, remember to add around 4 inches on each end for plugs. For longer distances, the measurement factor becomes critical since it directly influences data transfer speeds. For example, cat6 cables support a data transfer rate of 10Gbps over 50 meters; however, this drops to 1Gbps over 100 meters. As a result, you must verify that your cable does not exceed the 100-meter restriction.
Strip the Cable
Measure 2 inches from the end of the wire. Then, in the cable strippers, place your Bulk Cat6 Cable 1000ft. Squeeze the cable snugly but not too tightly. Make sure your wire stripper's blade is perpendicular to the wire. Turn the stripper around the wire once to score the cable's sheathing. Remove the stripper and bend the ethernet cable parallel to the scoreline. Sheathing will be broken as a result of this activity. Remove and discard the broken covering from the Cat6 cable.
Preparing Inner Cables
The Cat6 Riser Pure Copper Cable conductors are no longer twisted together in four pairs once the sheathing is removed. The wires for the data plug are then organized in the next phase. T-568B and T-568A are the two most common variants these days. Moving left to right, we recommend the following configuration:
White Orange
Orange
White Green
Blue
White Blue
Green
White Brown
Brown
After you've configured the cables, you'll straighten them as neatly as possible. You don't need to bother about even lengths at this point; instead, focus entirely on straightening out the cables. When pruning cables via cable clutter, however, you must ensure that all wires are even.
Crimp The Connectors to The Cable
Insert your Cat6 cable into the RJ45 connector now. After you've inserted the wires into the connector, ensure the sheathing is inside the data plug's end; this will increase signal strength and protect them from interference. As you pinch the cable higher and move it closer to the connector, the sheathing will be pushed farther into the RJ45 connector. Next, place the plugin in the crimping tool and squeeze the handle. Then, on the opposite end, repeat the process.
Testing Phase
Now use testers to check your patch wire. You're good to go if the results are perfect.
0 notes
newyorkcablesblog · 3 years ago
Photo
Tumblr media
Difference Between OM1,OM2,OM3 and OM4 Multimode Fibers
https://www.newyorkcables.com/fiber-optic-cables/
0 notes
newyorkcablesblog · 3 years ago
Text
Plenum Cable Types & Specifications: Cat5e, Cat6, and Cat6a
Plenum cables are cables with CMP-rated jackets that are suitable for installation in the plenum spaces of buildings. All Ethernet cables, including Cat6 cable, Cat6a cable, and Cat5e cable, have CMP-rated jackets.
Let's start with a definition of plenum spaces before we go into the details:
Plenum Spaces
Plenum spaces are areas of a building where air circulation for air conditioning and heating systems is facilitated. Plenum spaces accomplish this by allowing conditioned/heated or return air to flow at a higher atmospheric pressure.
Plenum Cables
Plenum cables, as previously indicated, are those having CMP-rated jackets. Communication Multipurpose Cable, Plenum is the abbreviation for Communication Multipurpose Cable, Plenum. The jacket material received the highest CMP grade in the industry. CMP-marked cables are composed of the highest-quality PVC (polyvinyl chloride) material. Due to the harsh temperature conditions in plenum spaces, ethernet cables placed here should be of the highest quality jacket material. 
The plenum wires are fire-resistant and prevent the spread of fire. Plenum cables or CMP-rated cables release no smoke or harmful gases when exposed to a fire. Plenum cables are also UV resistant, making them an excellent choice for both residential and commercial installations. The plenum cables' thick coating also provides excellent protection against alien crosstalk, near-end crosstalk, and EMI (electromagnetic interference).
Plenum cables are classified as follows:
Plenum Cat5e Cable
Plenum Cat6 Cable
Plenum Cat6a Cable
Cat5e Plenum Cable Specifications
A CMP-rated jacket is included with a Cat5e plenum cable. It has a 1Gbps (Gigabits per second) data transfer rate over a distance of 50 meters (164 feet) and 100Mbps over a distance of 100 meters (328 feet). Although the TIA/EIA standard for bandwidth capabilities is 100MHz, several manufacturers make Cat5e cables with bandwidth capabilities up to 350MHz.
Pure copper conductors and CCA (copper-clad aluminum) conductors are also available in Cat5e plenum cable. In every way, cables with pure copper conductors outperform those with CCA conductors in terms of performance. This cable is also available in UTP and STP versions. Unshielded twisted pair is referred to as UTP, whereas shielded twisted pair is referred to as STP. In locations where high EMI is prevalent, STP cables are preferable, whereas UTP cables are used in environments where EMI is not an issue. STP cables are significantly more costly than UTP cables.
The wire gauge of Cat5 cable ranges from 22AWG to 26AWG (depending on the manufacturer)
Cat6 Plenum Cable Specifications
Cat6 Plenum cable is defined as a Cat6 cable with CMP-rated jackets. The properties of the jacket are the same as those covered in the previous sections.
Cat6 plenum cable enables 10Gbps data transfer rates over a distance of 50 meters (164 feet) and 1Gbps over 100 meters (328 feet) when it comes to data speed. Cat6 cables have a bandwidth of 550MHz, which is sufficient for most applications. There are pure copper conductors as well as copper-clad aluminum conductors in these cables. Cat6 plenum cables marked with UTP are unshielded twisted pairs, whereas those marked with STP are shielded twisted pairs.
The wire gauge of the Cat6 cable ranges from 22AWG to 26AWG (depending on the manufacturer).
Cat6a Plenum Cable Specifications
A Cat6 Plenum cable is a Cat6a cable with a CMP-rated covering. The jacket features the same thick covering, fire resistance, and UV resistance as the previous two cables.
The Cat6a Plenum cable delivers data transmission rates of 10Gbps over a distance of 100 meters in terms of data throughput. The wire's 750MHz bandwidth allows it to retain signal strength over greater distances. The wire gauge of the Cat6a cable ranges from 22AWG to 26AWG (depending on the manufacturer). High-speed applications such as 100BASE-XT Fast Ethernet, 10BASE-T, 1000BASE-T (IEEE802.3), 750MHz Broadband Video, and other secure networking applications commonly use the cable.
0 notes