#Selectable Flow Fire Fighting Pump Nozzles
Explore tagged Tumblr posts
midseo · 2 months ago
Text
High Pressure Fire Fighting Guns, Selectable Flow Fire Pump Nozzles
We are Manufacturer, Supplier, Exporter of High Pressure Fire Fighting Guns, Selectable Flow Fire Pump Nozzles from Kolhapur, Maharashtra, India.
0 notes
simsinter · 3 months ago
Text
The Essential Guide to Fire Fighting Equipment
Fire fighting equipment plays a critical role in safeguarding lives and properties from the devastating effects of fire. As fire incidents can occur unexpectedly, having the right equipment readily available is essential for effective response and prevention. This guide will explore the various types of fire fighting equipment, their uses, and the importance of regular maintenance and training.
Types of Fire Fighting Equipment
Fire Extinguishers: These are one of the most recognizable fire fighting tools. They come in various types, including water, foam, dry powder, carbon dioxide (CO2), and wet chemical extinguishers. Each type is designed to combat specific classes of fire. For instance, foam extinguishers are effective against flammable liquids, while CO2 extinguishers are ideal for electrical fires. Proper training in selecting and using the right extinguisher can make a significant difference in emergency situations.
Hoses and Nozzles: Fire hoses are critical for delivering water to extinguish a fire. They are typically made of durable materials to withstand high pressure. Couplings and fittings ensure that hoses can be connected easily and securely. Nozzles allow firefighters to control the flow and spray pattern of water, which is vital in targeting the fire effectively.
Fire Trucks: Fire trucks are equipped with a variety of tools and equipment, including pumps, ladders, hoses, and specialized tools for rescue operations. They are essential for transporting firefighters and equipment to the scene of a fire quickly. Advanced models may also include aerial devices that allow firefighters to reach higher elevations.
Protective Gear: Personal protective equipment (PPE) is crucial for the safety of firefighters. This includes helmets, gloves, turnout gear, and breathing apparatus. These items are designed to withstand extreme temperatures, protect against smoke inhalation, and provide mobility while performing rescue operations.
Fire Alarms and Detection Systems: Early detection is key in preventing extensive fire damage. Fire alarms and smoke detectors alert occupants of a building to the presence of smoke or fire, enabling prompt evacuation and response. Regular maintenance and testing of these systems are vital to ensure they function correctly.
Sprinkler Systems: Automatic fire sprinkler systems can suppress or control a fire before firefighters arrive on the scene. These systems are often integrated into building designs and activate when a certain temperature is reached, releasing water to control the blaze.
Tumblr media
Importance of Regular Maintenance
Having fire fighting equipment is only part of the equation; regular maintenance is equally crucial. Equipment should be inspected, tested, and serviced according to local regulations and manufacturer recommendations. For example, fire extinguishers need to be checked monthly for accessibility and pressure, while hoses should be inspected for wear and tear. Regular training sessions for personnel on how to use fire fighting equipment effectively can also improve response times and effectiveness during emergencies.
Training and Preparedness
Training is essential for anyone who may need to use fire fighting equipment. Fire drills should be conducted regularly to familiarize all occupants with emergency procedures, the location of equipment, and proper use. Understanding how to respond in a fire emergency can save lives and minimize property damage.
Conclusion
Investing in quality fire fighting equipment and ensuring it is properly maintained can significantly impact safety and preparedness. Whether in residential, commercial, or industrial settings, being equipped and trained to handle fire emergencies is vital. Remember, when it comes to fire safety, preparation is key. Always prioritize regular maintenance, training, and awareness to ensure effective fire response when it matters most. For more details visit our website: www.simsinter.com
0 notes
certainmiraclefun · 3 years ago
Text
IMPORTANCE OF FIRE HOSE SIZE
When arriving on the scene of a fire, emergency crews have to make quick, on-the-spot decisions for approaching the situation. Arguably, one of the most crucial determinations that needs to be made is which hose lines are best suited for the circumstances. Fire severity, type of property, amount of required hose, and suppression tactics are all factors that influence what size and type of hose should be used. Choose correctly; the blaze has a better chance of being contained. Get it wrong; the situation can take a turn for the worse. Two essential hoses operated by firefighters are attack and supply hoses. In this article, the BullDog Hose team highlights why hose size matters when approaching a fire.
Attack Lines
Attack hoses, such as BullDog’s Hi-Combat II®, Firepower II™, Ultima™, and Fireguard™, are designed to tackle fires in their beginning stages and offer flexible approaches to different types of fires. The most common attack line sizes that fire departments deploy are 1.75 inches and 2.5 inches. Both sizes have pros and cons, depending on the situation at hand. Deciding to work with one format over the other can dictate the effectiveness of the initial suppression efforts. Smaller diameter hoses require much higher pressure to move lower volumes of water.
When working with the 1.75-inch hose, it is most useful for taking on residential and vehicle fires. This hose size is much lighter and more maneuverable than the 2.5-inch line. A more compact design makes it easier for firefighters to move the line through hallways, stairwells, and small rooms. Generally, this hose can be operated by two to three firefighters and can deliver water around 140 to 200 gallons per minute (gpm). So this is the desired hose to utilize when suppressing smaller fires. Being relatively easier to manage, 1.75-inch hoses tend to be a ‘catch-all’ when first responding to a fire. If attempting to tackle larger blazes, the 2.5-inch attack hose should be fielded.
A 2.5-inch hose line is the best choice when responding to more significant commercial buildings and exterior fires. With the ability to deliver high volumes of water at 200 to 300 gpm, this hose can take on more of the fire load than the smaller 1.75-inch attack line. The 2.5-inch hose can be more challenging to control in smaller spaces and is commonly handled by three to four firefighters.
Supply Lines
Keeping the attack lines charged and operating at their best efficiency all depends on the supply hoses. These hoses, like BullDog’s Hi-Vol® and Hi-Vol TPU™, can be found in sizes ranging from 3 to 6 inches in diameter. The bigger supply lines move high volumes of water from hydrants and fire engines to the attack lines. With the larger diameter, supply hoses can carry more water at lower pressures. Relocating supply lines can be difficult once the water begins flowing.
Fire fighting is one of the professions that keeps our nation thriving. But, fire departments around America have to select the best hoses every year. Budgets might change and the seasons grow warmer, but safety is of utmost importance. However, not every fire hose works the same due to the fires they have to fight. So, let’s learn about the big differences between municipal and industrial fire hoses.
Municipal Fire Hoses
Municipal Fire Hoses are designed for fire fighting that requires kink resistance and critical water flow. Being lightweight is key, as these hoses often have to deal with shifting terrain and various on-the-job changes. While older and more standard municipal fire hoses are maximized for normal wear and tear, what about the specialty hoses?
There are a variety of municipal fire hoses on the market to solve any problem your fire department or town might be facing. Need hoses to be more cost conscious, solutions are available. What about municipal hoses needed to reach high rise or raised angle structures? There are fire hoses for that as well.
Pumping to high-rise buildings in cities vs. rural settings is also a concern faced by these same municipal fire hoses. Depending on the structures you protect, you will need to consult with your hose supplier to find out which one works the best for you.
Industrial Fire Hoses
Industrial Fire Hoses pack a little more punch than the typical municipal fire hose. They feature far superior heat and abrasion resistance. Plus, they tend to be able to support issues concerning oil, fuel and chemicals far greater than the typical municipal fire hose. The industrial fire hoses tend to be flexible and lightweight as well.
These fire hoses also tend to be optimized to be maintenance free. While that doesn’t mean you won’t have to take care of industrial fire hoses, it means maintenance demands will be fewer. The practical uses of the industrial fire hoses remain the same in theory. You’re going to transfer liquid, washdown areas and generally solve problems.
However, municipal fire fighting hose belong to the typical mental image you have day-to-day fire fighting. Meanwhile, industrial fire hoses are used on air strips, military bases, heavy industrial factories and related business areas.
What kind of fire fighting hose are you going to need?
As time marches on deeper into the year and your budget deadline grows close, you will have to address your fire fighting needs. No one wants to be the person that reaches for a fire hose only not have it be suited for the purpose at hand. Whether you’re outfitting your local rural fire department or keeping an auto plant safe, you must know the differences between municipal and industrial fire hoses.
Is there really a best fire fighting hose?
Well, it depends on the environment and overall purpose. Industrial forestry fire hose can fight all sorts of fires started by various things, but they do this in fixed environments.
Municipal fire hoses save towns money. They also are ready to suction water out of unusual water resources. Then, there is the method of actual dispersing the fire.
A municipal fire hose extinguishes a fire with limited structural damage and loss of life. The industrial fire fighting hose keeps fire from accelerating. Stopping the acceleration means it doesn’t spread to other structures that might combust in a short amount of time. The power in an industrial fire hose will keep a plane from exploding, but it also can punch holes in an unstable wall during a house fire.
In the end, the best fire hose is determined by the purpose and the individual. Keep reading and visiting Bulldog Hose to learn more about the world of fire fighting hose.
Fire hoses are constantly in demand in our ever-changing world. But, if you’re trying to meet a municipal budget, where do you turn? Your friends at BullDog Hose have been helping fire departments around the US and Canada discover their perfect work balance. Finding the needs to meet safety with the durable hoses that would break a fire department’s budget.
Big Hoses that don’t break the bank
When people think of fire hoses, their background changes their opinion of them. Older veteran firefighters remember the thick monstrous hoses of the 1970s that made high-rises difficult to navigate. While most fire houses have gotten rid of those bulky behemoths, what are they doing in 2021?
The answer is simple for many fire fighters and fire departments around the US and Canada. They’re struggling with big hoses from a bygone era that aren’t getting the job done. Couplings are worn or a little off. If that wasn’t enough, the same fire fighters are having to keep up with changing fire fighting standards.
What is the right size hose for fire fighting and attack?
Fire fighting and fire attack have several unique demands. First, they have to be able to be used and save lives. Second, the fire fighting hose costs can’t break the Department’s budget. Finally, they have to be perfectly adapted to fit and attack fires in the most accurate way.
The idea of big fire needs big water is traditionally heard in fire fighting. That has lead to the majority of fire departments purchasing larger hoses ala something with a 2 1/2 inch handline. While this standard was applied for years without any consideration towards fire fighting needs, the National Fire Academy found a formula to help you pick the best hose.
Length x Width / 3  x Rate of Involvement
So, let’s say you have a 25 foot length of hose and the width of a building is 40 feet that is 25% on fire.
25 x 40 = 1,000 square feet
1,000 divided by 3 is 333.3
333 x .25 = 83.25 gallons per minute.
The benefits of knowing the right size suction hose formula
The NFA formula allows fire departments to measure and understand what they need on the fly. While this is helpful for online and in-person shopping, these modern mathematic applications help your Fire Department save money. Times are tough and budgets aren’t what they used to be, but every municipality and bigger city needs fire fighting materials.
BullDog Hose has Fire Hoses for Sale
At BullDog Hose, we have many fire hoses for sale. But, which is best for you? While we’ve discussed the need to keep an eye for the best fit, provided a formula to figure out your needs and guided you in your journey…what’s next?
Examine our Top 5 hoses for Fire Departments
Attack Fire Hoses
Hi-Combat II
Supply Line Fire Hoses
Hi-Vol
General Fire Hoses
While browsing the marine hose for Sale, don’t forget to look at the Fireguards
Fireguards are a very aggressive fire hose meant for interior attack. Too often, we see Fire Departments only concentrating on their immediate needs for external fires. The special weave and flexibility of the Fire Guard aids transport and helps for specialized fire fighting. During the summer, public fire fighting statements have shown that that fireguards can assist with waterside related fire needs.
Don’t forget to check out the fire nozzles. Do you need a fog nozzle or a smoothbore nozzle?
Smoothbore nozzles have an open path from coupling to nozzle tip. If you want to create different kinds of streaming patterns, you’re going to want a fog nozzle. The traditional firefighter will find what they need with a smoothbore nozzle. However, there is an added benefit to having the ability to apply different kinds of pressure depending on what a situation needs.
You have a choice in purchasing municipal fire hose, make sure you pick the best with BullDog Hose.
1 note · View note
rs12345 · 3 years ago
Text
Major Applications Of Open Circuit SBA
Open circuit training is useful in emergency rescue, fire fighting and other disaster response situations. As oil spills and other accidents cause massive releases of organic pollutants into the air, open circuit scba is a great way to protect the wearer's health. This type of breathing apparatus circulates open circuit gas through the open circuit system within the helmet. Although this type of respirator has been around for decades, there are many new developments and advantages to open circuit scuba as well.
An open circuit scuba will protect a wearer by providing increased resistance to external forces that could cause pressure inside the mask. There are many reasons why the level of open circuit pressure inside an air mask varies from one individual to another. The amount of open circuit pressure inside the mask depends on the design of the face mask and the shape of the wearer's head.
https://www.reportmines.com/advanced-car-audio-market-in-southeast-asia-r185377 https://www.reportmines.com/advanced-car-audio-market-in-brazil-r185378 https://www.reportmines.com/advanced-car-audio-market-in-indonesia-r185379 https://www.reportmines.com/advanced-car-audio-market-in-thailand-r185380 https://www.reportmines.com/advanced-car-audio-market-in-vietnam-r185381
A negative pressure inside a mask could cause the windpipe to become obstructed and create a reduced airflow through the mask. The open circuit scuba may reduce the force of the wind and improve the resistance through the mask. A positive pressure could cause the head to tilt forward slightly, which may open the windpipe by allowing pressurized air to escape. This type of open-circuit scuba may reduce irritation of the skin caused by open circuit pressure as well as improving the wearer's ability to swim.
Many factors can change the open circuit pressure of a person's helmet. The degree of incline on the head could greatly affect the amount of open circuit gas present in the system. Different types of helmets have different numbers of slopes on their faces. The presence of curves or ridges on the front or sides of a scuba mask can add to the open circuit of a helmet. The amount of open circuit that can be experienced by the wearer is dependent upon the amount of force that can push into the open circuit lines of the helmet.
Open circuit control is determined by the open-circuit scuba and atmospheric pressure. The open circuit scba is measured in millibars and open circuit pressure is expressed as a percentage of this measurement. Less than 100% open circuit scba research will provide protection against open circuit problems while high levels will prevent open circuit scuba from providing protection. For example, if the wearer has a headlamp equipped with a high intensity discharge (HID) bulbs and open circuit scba level is three hundred millimeters open circuit would prevent light from reaching the rider's eyes. High levels of open circuit scuba will prevent the rider from tilting his head back when using his helmet.
For open circuit safety, it is recommended that open circuit devices be used with some type of breathing apparatuses such as a breathing mask. The breathing apparatuses should be properly selected according to the size of the open circuit device, its shape, the size of the rider's face, his hand's strength, and his habit. In other words, if the rider has a long face, he will need a breathing apparatuses with larger openings for air flow.
Other open circuit scuba equipment is available such as breathing apparatus valves and valve regulators. These breathing apparatus devices allow the rider to open his mouth and breathe by just pressing a button. It is recommended that such breathing apparatus is worn on the side of the helmet rather than on top as the airflow coming through the open circuit tubing can be obstructed. A breathable air cylinder is also recommended for riders as this will allow air exchange between the rider's mouth and the open circuit tubing thereby reducing condensation.
Another major application of open circuit scuba equipment is firefighting. There are numerous firefighting equipment used in open circuit fire trucks, including fire hose reels and fire hydrants. The firefighting firemen use open circuit fire apparatus equipped with a hand held fireside mask. The fire hose reel is connected to a firefighting nozzle via an extending hose with a flexible end. This apparatus allows the firemen to spray water in a targeted area. The open circuit equipment may also have provisions for storing water in the hose reel to be used for cleaning up afterwards.
Summary
The report forecast global Open-Circuit SCBA market to grow to reach xxx Million USD in 2019 with a CAGR of xx% during the period 2020-2025 due to coronavirus situation.
The report offers detailed coverage of Open-Circuit SCBA industry and main market trends with impact of coronavirus. The market research includes historical and forecast market data, demand, application details, price trends, and company shares of the leading Open-Circuit SCBA by geography. The report splits the market size, by volume and value, on the basis of application type and geography.
First, this report covers the present status and the future prospects of the global Open-Circuit SCBA market for 2015-2024.
And in this report, we analyze global market from 5 geographies: Asia-Pacific[China, Southeast Asia, India, Japan, Korea, Western Asia], Europe[Germany, UK, France, Italy, Russia, Spain, Netherlands, Turkey, Switzerland], North America[United States, Canada, Mexico], Middle East & Africa[GCC, North Africa, South Africa], South America[Brazil, Argentina, Columbia, Chile, Peru].
At the same time, we classify Open-Circuit SCBA according to the type, application by geography. More importantly, the report includes major countries market based on the type and application.
Finally, the report provides detailed profile and data information analysis of leading Open-Circuit SCBA company.
Key Content of Chapters as follows (Including and can be customized) :
Part 1:
Market Overview, Development, and Segment by Type, Application & Region
Part 2:
Company information, Sales, Cost, Margin etc.
Part 3:
Global Market by company, Type, Application & Geography
Part 4:
Asia-Pacific Market by Type, Application & Geography
Part 5:
Europe Market by Type, Application & Geography
Part 6:
North America Market by Type, Application & Geography
Part 7:
South America Market by Type, Application & Geography
Part 8:
Middle East & Africa Market by Type, Application & Geography
Part 9:
Market Features
Part 10:
Investment Opportunity
Part 11:
Conclusion
Market Segment as follows:
By Region
Asia-Pacific[China, Southeast Asia, India, Japan, Korea, Western Asia]
Europe[Germany, UK, France, Italy, Russia, Spain, Netherlands, Turkey, Switzerland]
North America[United States, Canada, Mexico]
Middle East & Africa[GCC, North Africa, South Africa]
South America[Brazil, Argentina, Columbia, Chile, Peru]
Key Companies
MSA
Scott Safety
Honeywell
Drager
Interspiro
Cam Lock
Shigematsu
Avon
Matisec
Sinoma
Koken
Market by Type
High Pressure Open-Circuit SCBA
Low Pressure Open-Circuit SCBA
Market by Application
Fire Fighting
Industrial Use
Other Use
Frequently Asked QuestionsWhat is the USP of the report?
Global Open-Circuit SCBA Market report offers great insights of the market and consumer data and their interpretation through various figures and graphs. Report has embedded global market and regional market deep analysis through various research methodologies. The report also offers great competitor analysis of the industries and highlights the key aspect of their business like success stories, market development and growth rate.
What are the key content of the report?What are the value propositions and opportunities offered in this market research report?Related Reports
Global Open Peripheral Pump Market
Global Online K 12 Education Market
Global Oncology Information System Market
Contact us: https://www.reportmines.com/contact-us.php
0 notes
researchetcsblog · 4 years ago
Text
Major Applications Of Open Circuit SBA
Open circuit training is useful in emergency rescue, fire fighting and other disaster response situations. As oil spills and other accidents cause massive releases of organic pollutants into the air, open circuit scba is a great way to protect the wearer's health. This type of breathing apparatus circulates open circuit gas through the open circuit system within the helmet. Although this type of respirator has been around for decades, there are many new developments and advantages to open circuit scuba as well.
An open circuit scuba will protect a wearer by providing increased resistance to external forces that could cause pressure inside the mask. There are many reasons why the level of open circuit pressure inside an air mask varies from one individual to another. The amount of open circuit pressure inside the mask depends on the design of the face mask and the shape of the wearer's head.
A negative pressure inside a mask could cause the windpipe to become obstructed and create a reduced airflow through the mask. The open circuit scuba may reduce the force of the wind and improve the resistance through the mask. A positive pressure could cause the head to tilt forward slightly, which may open the windpipe by allowing pressurized air to escape. This type of open-circuit scuba may reduce irritation of the skin caused by open circuit pressure as well as improving the wearer's ability to swim.
Many factors can change the open circuit pressure of a person's helmet. The degree of incline on the head could greatly affect the amount of open circuit gas present in the system. Different types of helmets have different numbers of slopes on their faces. The presence of curves or ridges on the front or sides of a scuba mask can add to the open circuit of a helmet. The amount of open circuit that can be experienced by the wearer is dependent upon the amount of force that can push into the open circuit lines of the helmet.
Open circuit control is determined by the open-circuit scuba and atmospheric pressure. The open circuit scba is measured in millibars and open circuit pressure is expressed as a percentage of this measurement. Less than 100% open circuit scba research will provide protection against open circuit problems while high levels will prevent open circuit scuba from providing protection. For example, if the wearer has a headlamp equipped with a high intensity discharge (HID) bulbs and open circuit scba level is three hundred millimeters open circuit would prevent light from reaching the rider's eyes. High levels of open circuit scuba will prevent the rider from tilting his head back when using his helmet.
For open circuit safety, it is recommended that open circuit devices be used with some type of breathing apparatuses such as a breathing mask. The breathing apparatuses should be properly selected according to the size of the open circuit device, its shape, the size of the rider's face, his hand's strength, and his habit. In other words, if the rider has a long face, he will need a breathing apparatuses with larger openings for air flow.
Other open circuit scuba equipment is available such as breathing apparatus valves and valve regulators. These breathing apparatus devices allow the rider to open his mouth and breathe by just pressing a button. It is recommended that such breathing apparatus is worn on the side of the helmet rather than on top as the airflow coming through the open circuit tubing can be obstructed. A breathable air cylinder is also recommended for riders as this will allow air exchange between the rider's mouth and the open circuit tubing thereby reducing condensation.
Another major application of open circuit scuba equipment is firefighting. There are numerous firefighting equipment used in open circuit fire trucks, including fire hose reels and fire hydrants. The firefighting firemen use open circuit fire apparatus equipped with a hand held fireside mask. The fire hose reel is connected to a firefighting nozzle via an extending hose with a flexible end. This apparatus allows the firemen to spray water in a targeted area. The open circuit equipment may also have provisions for storing water in the hose reel to be used for cleaning up afterwards.
Summary
The report forecast global Open-Circuit SCBA market to grow to reach xxx Million USD in 2019 with a CAGR of xx% during the period 2020-2025 due to coronavirus situation.
The report offers detailed coverage of Open-Circuit SCBA industry and main market trends with impact of coronavirus. The market research includes historical and forecast market data, demand, application details, price trends, and company shares of the leading Open-Circuit SCBA by geography. The report splits the market size, by volume and value, on the basis of application type and geography.
First, this report covers the present status and the future prospects of the global Open-Circuit SCBA market for 2015-2024.
And in this report, we analyze global market from 5 geographies: Asia-Pacific[China, Southeast Asia, India, Japan, Korea, Western Asia], Europe[Germany, UK, France, Italy, Russia, Spain, Netherlands, Turkey, Switzerland], North America[United States, Canada, Mexico], Middle East & Africa[GCC, North Africa, South Africa], South America[Brazil, Argentina, Columbia, Chile, Peru].
At the same time, we classify Open-Circuit SCBA according to the type, application by geography. More importantly, the report includes major countries market based on the type and application.
Finally, the report provides detailed profile and data information analysis of leading Open-Circuit SCBA company.
Key Content of Chapters as follows (Including and can be customized) :
Part 1:
Market Overview, Development, and Segment by Type, Application & Region
Part 2:
Company information, Sales, Cost, Margin etc.
Part 3:
Global Market by company, Type, Application & Geography
Part 4:
Asia-Pacific Market by Type, Application & Geography
Part 5:
Europe Market by Type, Application & Geography
Part 6:
North America Market by Type, Application & Geography
Part 7:
South America Market by Type, Application & Geography
Part 8:
Middle East & Africa Market by Type, Application & Geography
Part 9:
Market Features
Part 10:
Investment Opportunity
Part 11:
Conclusion
Market Segment as follows:
By Region
Asia-Pacific[China, Southeast Asia, India, Japan, Korea, Western Asia]
Europe[Germany, UK, France, Italy, Russia, Spain, Netherlands, Turkey, Switzerland]
North America[United States, Canada, Mexico]
Middle East & Africa[GCC, North Africa, South Africa]
South America[Brazil, Argentina, Columbia, Chile, Peru]
Key Companies
MSA 
Scott Safety 
Honeywell 
Drager 
Interspiro 
Cam Lock 
Shigematsu 
Avon 
Matisec 
Sinoma 
Koken
Market by Type
High Pressure Open-Circuit SCBA 
Low Pressure Open-Circuit SCBA 
Market by Application
Fire Fighting 
Industrial Use 
Other Use
Global Open-Circuit SCBA Market report offers great insights of the market and consumer data and their interpretation through various figures and graphs. Report has embedded global market and regional market deep analysis through various research methodologies. The report also offers great competitor analysis of the industries and highlights the key aspect of their business like success stories, market development and growth rate.
Global Open Peripheral Pump Market
Global Online K 12 Education Market
Global Oncology Information System Market
Contact us: https://www.reportmines.com/contact-us.php 
0 notes
alvinashah2018-blog · 6 years ago
Text
The firefighting equipment of the tigon. Powerful and distinctive
Industrial firefighting vehicles have to fulfill the best firefighting equipment needs. The tigon even exceeds these needs, since this special vehicle is capable of pump & roll operation and has 2 separate foam proportioning systems.
A rather uncommon feature for industrial firefighting vehicles, as this can be predominantly utilized in municipal vehicles and is that the normal demand for fire fighting vehicles. If even higher pump outputs are needed, the Volvo drive motor is powerful enough to drive even the latest inbuilt pump.
The roof turret of the tigon will – specifically additionally whereas driving – be ergonomically controlled from the control handle. The direction of the management handle determines the direction of the turret, with that the turret are often operated improbably sensitively and intuitively, whether or not you would like to stay your eyes on the road, as an example.
All turrets will be fitted with the CHEMCORE nozzle, with that dry powder may be output directly within the center of the water stream. This allow the right combination of the positive properties of water and powder.
Even at the vehicle design stage it absolutely was important that the firefighting technology may be utilized in a minimum of as many alternative ways in which because the chassis, so as to offer customers the best possible flexibility for (almost) every conceivable extinguishing application.
Choosing the correct extinguishing system
There is no single good extinguishing system for every type {of fireplace} and fire sizes. Once it involves procurance, a fire department is usually faced with the decision of selecting the right extinguishing system supported the potential dangers it faces.
EFFPL offers a broad portfolio of extinguishing systems for all applications supported the specified flow rates, extinguishing efficiency and vehicle ideas. Due to the upper discharge speed at the nozzle, the foam pipe of the NEPIRO nozzle produces a much more homogeneous and stable foam than normal-pressure extinguishing systems.
All manufacturers of firefighting equipment claim, or a minimum of strive, to concentrate closely to their customers. However what they really do with the information varies. Our mixture of tried-and-tested, advanced pump technology, combined with a contemporary, powerful motor and countless detailed improvements are specifically what our customers expect of our most recent pumps!
Our unique pump design combined with clever choices supports operators to prevent damage to the pump when they are distracted, which frequently happens in disagreeable situations. Another innovation is our new pump material, duplex stainless-steel.
Duplex stainless steel consists of a steel alloy of 2 steel teams. The primary steel cluster is characterized by high corrosion resistance (austenitic steel) and also the second by high resistance (ferritic steel). The alloy combines the benefits of each steel teams. The duplex stainless steel we use for our pumps is lighter and a lot of resistant to abrasion than bronze.
Fire-fighting equipment for indoor firefighting may be tested in fire containers equipped with acceptable measuring equipment to live temperature changes in the room. In some cases, we also do this in collaboration with customers who need to jointly value extinguishing procedures. This can be an exciting cooperation with experienced practitioners who need to additional develop current technology and tactics.
Leading Fire Fighting Systems Manufacturer, with combined normal pressure / high pressure pumps. The pump will extinguish with high pressure misting or normal, and, if need be, each at the same time. The high-pressure mist extinguishing method achieves the greatest possible extinguishing effect with the minimum amount of water.
0 notes
aaagindia · 7 years ago
Link
Q1. What is the purpose of handline firefighting branches and nozzles?
Q2. What are the basic types of handline nozzles?
Q3. What are the shortcomings of short branch with nozzle?
Q4. What are the advantages and shortcomings of the basic spray (combination) nozzle?
Q5. How are constant flow nozzles different from Combination nozzles?
Q6. What are the advantages of using a selectable flow nozzle?
Q7. What are automatic nozzles and how do they function?
Q8. How is quality of fog improved by providing teeth on nozzle outlets?
Q9. As far as quality of fog is concerned, how do spinning teeth compare with solid teeth?
Q10. Which type of valves are provided on handline firefighting nozzles?
Q11. What are the factors to be considered when procuring firefighting handline branches?
Q12. What are the normal maintenance requirements for handline nozzles?
Q1. What is the purpose of handline firefighting branches and nozzles?
To fight small and medium size fires, it is necessary to direct water from a safe distance onto the fire area, in the required form (large/ small droplets). Pressurized water can be conveyed to the affected area using fire fighting hoses. However, to project it to the fire area, it is required to convert the pressure energy of the water into velocity energy. At the same time, it is necessary to project the water in the desired form i.e. jet, spray or fog, to ensure maximum effectiveness depending upon the situation. Handline firefighting branches and nozzles do the job of converting the pressure energy to velocity energy and projecting the water in the required form.
Q2. What are the basic types of handline nozzles?
There is no standard classification of handline nozzles, as they can be sub-divided into different types depending upon on pattern, flow quantity, etc. Normally they are classified as follows –
Solid bore nozzles (which discharge water in form of a solid jet only)
Combination or Spray nozzles (or Jet/Spray type nozzles) which discharge in form of a hollow jet, narrow fog or wide fog. These can be further sub-divided into –
Multipurpose nozzles (those discharging water in form of a solid jet as well as spray, even simultaneously).
Constant flow nozzles (those discharging same flow at a given pressure)
Variable flow nozzles (flow can be varied manually for a given pressure)
Automatic nozzles (flow varies depending upon pressure)
Q3. What are the shortcomings of short branch with nozzle?
In short branch with nozzle, the pattern of flow is only in form of a solid jet, which means that this branch is unable to project water in form of fog, or spray for protection. At the same time, due to the absence of a valve in the nozzle, it could not be shut off by the nozzle man, which means that he has no control over the branch.
Q4. What are the advantages and shortcomings of the basic spray (combination) nozzle?
The main advantage of the combination or spray nozzle is that it is provided with a pattern changeover mechanism as well as a shut off arrangement. The pattern changeover mechanism allows changing the pattern from jet to spray or vice-versa, while the shut-off mechanism allows the operator to shut down the flow, when required.
In the basic spray nozzle, the flow varies as the pattern changes from the hollow jet to the spray pattern (normally the flow in jet pattern is lesser and increases as the pattern changes to fog)
Q5. How are constant flow nozzles different from Combination nozzles?
In certain combination nozzles, the flow changes with pattern. However, in Constant flow nozzles (also known as Single gallonage nozzles), the flow remains constant throughout the different range of discharge patterns i.e the flow will remain same whether discharging in form of a jet or spray.
Q6. What are the advantages of using a selectable flow nozzle?
Selectable flow nozzles incorporate an arrangement to vary the outlet orifice size, hence the flow can be varied by changing this orifice size. The operator can set the flow without shutting down the line, depending upon the pressure available, and other operational considerations. This means that the nozzle can be used effectively even in varying pressure conditions by the operator himself, without any dependence on the pump operator.
Q7. What are automatic nozzles and how do they function?
An automatic nozzle maintains a relatively constant pressure over a wide range of flows. Such nozzles have an arrangement in the nozzle which controls the flow by restricting the orifice outlet to maintain pressure.
If the pressure is relatively low, the nozzle orifice will automatically restrict the flow, causing pressure buildup at the outlet, and consequently resulting in a good quality discharge pattern. Similarly, if the pressure increases, the orifice opens to allow more flow, again adjusting to a constant pressure at the outlet of the nozzle.
Q8. How is quality of fog improved by providing teeth on nozzle outlets?
Providing teeth on the nozzle outlet serves two purposes; first, in the narrow fog position, it deflects part of the water to the centre of the spray (which is otherwise hollow). Secondly, in the wide fog position, it caused the water curtain to break up into streams which then impinged on one another to create a better quality fog. A variety of different designs of teeth (fixed/ spinning/ flexible) can be used to create this fog.
Q9. As far as quality of fog is concerned, how do spinning teeth compare with solid teeth?
There is no clear research data to prove superiority of spinning teeth over solid teeth. Certain trials show that spinning teeth rotating in the fog position, cause the break up of the water curtain into fine droplets, which are ideal for fire gas cooling operations. It may be noted, however, that there is no conclusive evidence on the superiority of spinning teeth.
Q10. Which type of valves are provided on handline firefighting nozzles?
For a long time, manufacturers have been using the ball valve for controlling the flow in the nozzle, as it is a proven design, operates well at the pressures used, and is relatively maintenance free. The ball can be of metal, or polymer based materials.
Another type of valve used nowadays is the slide valve, in which a hollow cylinder moves back and forth along the central axis, and seals against a polymer seat. Due to the movement of the cylinder, it causes a variation in the orifice gap between the cylinder and the seat and hence controls the flow.
Q11. What are the factors to be considered when procuring firefighting handline branches?
When procuring handline nozzles, the following factors are normally considered –
Suitability to risk (whether the nozzle is suited to the type of fires likely to be encountered)
Pattern & Flow range (what are the discharge patterns available & whether nozzle flow is suited to risk and to the operators).
Material of construction
Maintenance and durability
Ergonomics (whether comfortable to handle for the type of operators present)
Q12. What are the normal maintenance requirements for handline nozzles?
Maintenance requirements can vary from one handline nozzle to another. Simple jet nozzles require virtually no maintenance, while new combination nozzles can require periodic replacement of components. Normal maintenance activities include –
Periodic visual inspections (at least monthly)
Periodic operational tests (as mandated by manufacturer)
Periodic replacement of rubber washers/ O rings (as mandated by manufacturer).
Periodic replacement of valve seats/ springs/ spinning teeth (as mandated by manufacturer).
0 notes