Tumgik
#S5710-X-LI
hongtelecom-blog · 6 years
Text
RPS1800 Power Supply for Huawei Fixed Switches
RPS1800 Power Supply for Huawei Fixed Switches
Tumblr media
Huawei Campus Switch includes S1700, S2300, S2700, S3300, S3700, S5300, S5700, S600-E, S6300, S6700, S7700, S7900, S9300, S9300X, S9700, S12700 Series. In this article, HongTelecom will introduce the RPS1800 Power Supply for Huawei Fixed Switches.
RPS1800 Power Supply Product Support
Table 1 lists the mapping between switch models and the RPS1800 power supply.
Table 1 Mapping between switch…
View On WordPress
0 notes
thunderlinkcom · 6 years
Text
What Constraints on USB-based deployment of Huawei S5700 Series Switch
The file system format of the USB flash drive must be FAT32, and standard for the USB interface is USB2.0 (USB1.1 interface on the S5700LI). To ensure compatibility between USB flash drives and devices, use Huawei-certified USB flash drives to configure the Huawei devices. Table 2 lists the USB flash drives applicable to a switch.
Only one USB flash drive can be connected to a device.
In V200R005C00 and later versions, USB-based deployment using a smart_config.ini index file is supported, and this deployment mode is supported in a stack. The USB flash drive must be connected to the master switch of the stack. If it is connected to the standby switch or a slave switch, the USB-based deployment process will not start.
USB-based deployment using the usbload_config.txt index file can only be performed in a single switch, not a stack of multiple switches. In a stack of multiple switches, if the USB flash drive is connected to the standby switch or a slave switch, the USB-based deployment process will not start. If the USB flash drive is connected to the master switch, the USB indicator blinks red fast, indicating that the USB-based deployment fails. In this case, the switch records an error report including the following information: The usbload_config.txt index file cannot be used for USB deployment of a multi-member stack.
The S5710-X-LI, S5720SI, S5720S-SI, S6720EI, S6720S-EI, S5720EI and S5720HI series switches support only the smart_config.ini format.
The S5700S-28X-LI-AC, S5700S-52X-LI-AC, and S5700S-28P-PWR-LI-AC in the S5700S-LI series support only the smart_config.ini format.
Fields in an index file are restricted by the current system version. For example, if some fields in the index file are not supported by the current system version, these fields are invalid for an upgrade to a later version.
USB-based deployment is mutually exclusive with the SVF, web initial login mode and EasyDeploy functions.
More related:
S5700-28X-LI-24S-AC
S5701-28X-LI-AC
S5700-28C-EI-24S
0 notes
hongtelecom-blog · 5 years
Text
RPS1800 Power Supply for Huawei Fixed Switches
RPS1800 Power Supply for Huawei Fixed Switches
Huawei Campus Switch includes S1700, S2300, S2700, S3300, S3700, S5300, S5700, S600-E, S6300, S6700, S7700, S7900, S9300, S9300X, S9700, S12700 Series. In this article, HongTelecom will introduce the RPS1800 Power Supply for Huawei Fixed Switches.
RPS1800 Power Supply Product Support
Table 1 lists the mapping between switch models and the RPS1800 power supply.
Table 1 Mapping between switch…
View On WordPress
0 notes
thunderlinkcom · 6 years
Text
What Constraints on USB-based deployment of Huawei S5700 Switch
The file system format of the USB flash drive must be FAT32, and standard for the USB interface is USB2.0 (USB1.1 interface on the S5700LI). To ensure compatibility between USB flash drives and devices, use Huawei-certified USB flash drives to configure the Huawei devices. Table 2 lists the USB flash drives applicable to a switch.
Tumblr media
Only one USB flash drive can be connected to a device.
In V200R005C00 and later versions, USB-based deployment using a smart_config.ini index file is supported, and this deployment mode is supported in a stack. The USB flash drive must be connected to the master switch of the stack. If it is connected to the standby switch or a slave switch, the USB-based deployment process will not start.
USB-based deployment using the usbload_config.txt index file can only be performed in a single switch, not a stack of multiple switches. In a stack of multiple switches, if the USB flash drive is connected to the standby switch or a slave switch, the USB-based deployment process will not start. If the USB flash drive is connected to the master switch, the USB indicator blinks red fast, indicating that the USB-based deployment fails. In this case, the switch records an error report including the following information: The usbload_config.txt index file cannot be used for USB deployment of a multi-member stack.
The S5710-X-LI, S5720SI, S5720S-SI, S6720EI, S6720S-EI, S5720EI and S5720HI series switches support only the smart_config.ini format.
The S5700S-28X-LI-AC, S5700S-52X-LI-AC, and S5700S-28P-PWR-LI-AC in the S5700S-LI series support only the smart_config.ini format.
Fields in an index file are restricted by the current system version. For example, if some fields in the index file are not supported by the current system version, these fields are invalid for an upgrade to a later version.
USB-based deployment is mutually exclusive with the SVF, web initial login mode and EasyDeploy functions.
More related:
S5700-28X-LI-24S-AC
S5701-28X-LI-AC
S5700-28C-EI-24S
0 notes