SmartGen | HVR1000 will launch!
SmartGen digital voltage regulation board HVR1000 will launch!
HVR1000 digital voltage regulation board can automatically adjust the terminal voltage of genset by controlling the field current of the alternator exciter. It has four excitation adjusting modes: Automatic voltage regulation (AVR), Field current regulation (FCR), Reactive power regulation (VAR), Power factor regulation (PF). HVR1000 digital voltage regulation board has CAN BUS interface and communication follows SAE J1939-75 protocol. It has flexible and comprehensive fault protection, can read and configure parameters through USB interface by PC or Bluetooth by mobile APP software, which can be used in PMG (Permanent Magnet Generator), AREP (Auxiliary Winding Excitation Generator), SHUNT (Self Excitation Generator).
function and characteristics
1.With four excitation adjusting modes: Automatic voltage regulation (AVR), Field current regulation (FCR), Reactive power regulation (VAR), Power factor regulation (PF); 2.With over-excitation limit, under-excitation limit, stator current short-circuit protection and voltage frequency (U/F) regulation function; 3.Automatic voltage regulation (AVR) and field current regulation (FCR) modes have soft start function; 4.Excitation regulation control has two algorithms: PID and ADRC (Active Disturbance Rejection Control); 5.The parameters of PID algorithm and ADRC algorithm of four adjustment modes are independent; 6.Support digital input, analog voltage (-10-10)V input, analog voltage (0-6000)Ω input to adjust the output target value; 7.The secondary rated current of current transformer can be set to 5A or 1A; 8.It can continuously supply current of 7A (70℃ room temperature) or 10A (55℃ room temperature) At rated voltage of 63V or 125V. The short-time maximum current lasts for 10s at 11A (70℃room temperature) or 14A (55℃room temperature); 9.With load compensation (LAM) function; 10.With dropping function, load compensation function; 11.With CAN communication interface, the communication follows SAE J1939-75 protocol 12.With Bluetooth communication interface, parameter reading, configuration and real-time data monitoring can be carried out through mobile APP software; 13.With Type-C interface for parameter reading and configuration; 14.Can detect THDu, THDi; 15.With functions of gen overvoltage, undervoltage, overfrequency, underfrequency, high unbalanced voltage, high waveform distortion, gen loss alarm, excitation overvoltage and excitation overcurrent alarm detection; 16.Enable current transformer, it has the functions of gen overcurrent, short circuit, overpower, reverse power, low power factor, loss of excitation alarm, current imbalance and high current waveform distortion alarm detection; 17.Suitable for three-phase three-wire, single-phase two-wire, 200V/400V power supply and 50Hz/60Hz system; 18.With 4 programmable digital input ports; 19.With 2 programmable digital output ports; 20.With 1-way analog voltage input (-10-+10)V; 21.With 1-way analog resistance input (0-6000)Ω; 22.Real-time data curve analysis can be carried out through PC software or APP software (only applicable to Android version); 23.With running data record, event log and real-time clock; 24.With fault alarm data recording function, the alarm data interval can be set, and the maximum number of records is 5; 25.With IP20 protection class.
Parameters
For more functions, please consult the business manager of SmartGen and look forward to your choice! SmartGen, making control smarter!
www.smartgen.cn
0 notes
Text
Buy the best range of products from the Top UPS Battery Dealers
Tumblr media
Costa Power Industries Pvt. Ltd. sells and performs services on all of the leading manufacturer’s modular ups systems. Costa have ample of experience with modular ups battery backup for control applications and harsh environments. Continuity of process control is critical across a vast range of industrial markets : Waste Water, Biotech, Pharmaceutical, Transportation, Chemical, Food & Beverage, Semiconductor, Automotive & Renewable Energy. modular online UPS systems are designed for environments with prevalent fluctuations in electric power supply, power interruptions and cuts. Costa Power is market leader for modular ups suppliers, modular ups dealers for standard brand i.e. APC UPS, Vertiv UPS, Numeric UPS, Hitachi UPS, Microtek UPS & Delta UPS.
Costa Power is topmost in offering Modular UPS System to our customers. It is next generation product. It consists of 1 to 10 UPS modules of 10kVA each, a system controller, static switch module, and distribution block and others. It can be easily upgraded from 10kVA to 100kVA and is made for hot insertion as well. In this product, inverter is used for supplying power to load and it takes power by usage of AC input.
Other details :-
Range :- 10 – 500 KVA Modular UPS
The rectifier is controlled to recharge the battery and maintain it in charged condition. The battery is galvanically connected between the rectifier output and the inverter input on a common DC link.
Features :-
Unity Input PF and THDi of 5%, Truly Green Power.
Truly modular :- 1 to10 Hot Swap Plug-in modules of each 10KVA capacity allowing Upgrading UPS capacity from 10KVA to 500KVA.
True Online Battery according to IEC 62040-3.
High Overall efficiency of 96% and 98% during backup mode.
Lower heat dissipation of 333W per 10KVA single module.
Flexible to configure as 3/3, 3/1 & 1/1 Input/output configurations.
Built-in Redundancy of N 1.
Intelligent battery test facility.
Unique light and compact design.
Large LCD display of 4×40 Character with 256 event logging facility.
Independent charging system for every module.
https://youtu.be/w5VkGUxwVXc
0 notes
1122020 · 5 years ago
Text
@wretchedanddivine
Hey. Sup. I’m Raven, your acid bath princess of the darkness. I’m Tara. And we’re sitting here in Tara’s room rocking out to MCR and celebrating 2009 or the new year which we don’t really understand why people are making such a big deal about it because really, one more year is one more year that everyone’s closer to death (death). Whatever suit yourself humanity. Congratulations. Yeah, when you’re closer to death.
49K notes · View notes
daisyliu618 · 2 years ago
Photo
Tumblr media
Jeidar DT series 3/3phase IGBT rectifier and IGBT inverter UPS. a big thing with good materials. 1) DT series R,S,T All the 3phase are use IGBT module(from Mitsubishi), not just in R phase. and they are totally 3phase independent power control. means one phase have problem could pull the power module board out replcement, do not influence 2 other Phases. any phase miss or fault will Alarm and show fault on LCD 2) this UPS is transformer free model, but equipped 12pcs inductors for distortion and noise filting, which makes the THDI within 4% and overall efficiency under ECO model 98% 3), there are 9pcs speed control fans with size 120*120*38mm, each one have problem will be Alarm independently, and install in cacoordance with data center ventilation Standard 4), 2 DSP control in power section, another 1 DSP control in the charging board to control Bus+ and Bus- charging. the charger could control +/- in balance, which not make the battery bulge due to unbalance charging. battery qty also adjustable from 28-32pcs, 10-40KVA can put maximum 64pcs 7/9Ah battery internal 5) the main components from Internation famous brand, we buy the IGBT from mitsubishi, Cooling fan from Delta, Mccb from LS , Fuse from Eaton bussman etc #UPS #jeidarups #onlineUPS #highfrequencyUPS #UPS60KVA #UPS80KVA #UPS100KVA #UPS120KVA #DT #upsonline #upsmanufacyure #UPSsupplier #shenzhen #Kotohirasystem #uninterruptiblepowersupply https://www.instagram.com/p/Ce0glrMv5bv/?igshid=NGJjMDIxMWI=
0 notes
alliedindustrialmarketing · 3 years ago
Photo
Tumblr media
New Post has been published on https://www.alliedindustrialmarketing.com/mangoldts-harmonic-filter-kits/
Mangoldt's Harmonic Filter Kits - Finalist for the CSE Magazine
Mangoldt IHF Input Harmonic Filter Kit with Building Block Versatility!
Mangoldt’s Harmonic Filter Kits Please Vote! We are honored to inform you that Mangoldt’s Harmonic Filter Kits are a Finalist for the Consulting-Specifying Engineer Magazine “Product-of-the-Year-Award” in the Power Systems & Equipment category!
Voting is taking place now, and we would appreciate your help!
You can register and vote at: https://surveys.cfemedia.com/s3/votecse2021poy.
First Register at CSE magazine
Scroll down the page for category headings Heading: “Power Systems & Equipment”
Vote for Mangoldt Type IHF Kit. 
      The voting will end on September 10th, 2021, so we need your support.
We appreciate the recognition that Mangoldt’s IHF Harmonic Filter Kits are getting for their building blocks versatility and guaranteed harmonic distortion levels of 5%, 8% or 12% THD-i, with lower-cost options for VFDs with internal reactors.
In June, we were excited to debut our Input Harmonic Filter (IHF) kits at the EASA 2021 Convention in Fort Worth, Texas.  The IHF Filter Kits were well received by OEMs and System integrators alike.
Please check out the IHF Harmonic Filter Kits for yourself. Our VFD Input Harmonic Filters can achieve 5%, 8%, or 12% THDi in VFD applications and may also be used with DC drives and other 6-pulse AC to DC rectifiers.  Mangoldt IHF Harmonic Filter Kits are an excellent way for you to offer harmonic mitigation to broaden your product portfolio.
Did we mention the IHF Harmonic Filter Kits are affordable too?
Check us out today!  Here is a link to the Catalog & Selection Chart.  
IHF Input Harmonic Filter page
We strive to make a difference by partnering with our customers to protect electrical assets and production equipment. We look forward to hearing from you!
0 notes
cooldavidkentposts · 4 years ago
Text
Advanced pump system upgrade cuts AlburyCity Council costs
AlburyCity Council in NSW operates two water supply systems to manage and treat raw water to provide clear, potable water. The raw water scheme uses three pump stations to deliver raw water to the water filtration plant, where it is treated into safe and secure drinking water for 55,000 residents in Albury and the surrounding region. The council manages and supplies a separate raw water scheme that delivers untreated water to several large businesses in the area, including a paper mill, golf club and equestrian centre.
One section of the clear water reticulation system features a water-boosting pump station responsible for pumping to water storage tanks on a nearby hill. From here, the system uses gravity to distribute the treated water to nearby communities. It is on standby 24 hours a day, seven days a week, with actual pumping operations of between six hours per day in winter months and up to 16 hours per day during the summer months.
A result of many decades of steady development, the pumping station area now sits amongst various dwellings including a public school, as close as 20 m.
When equipment causes electrical disturbances
A problem was recognised in the power system each time the station’s pumps would start. It was causing a burdensome inconvenience and intrusive electrical disturbance whereby the lights in nearby buildings would dim each time the pumps were started or stopped.
In response, AlburyCity Council engaged ABB Channel Partner Remtron to conduct an analysis of the problem and provide a solution with long-term resolve.
Remtron identified that the power quality disturbance was caused by the system’s installed soft starter motor controller. Modern solid-state power conversion equipment (PCE), such as soft starters, is effective at soft starting a motor; however, the side effect is harmonic distortion introduced into the power network during the starting and stopping of the motor.
“When the soft starter would activate, the associated soft starting action created unwanted distortion on the power network,” said Anthony Merrett, Automation Support Engineer – Drives and Power Quality for Remtron.
The electrical stress caused by harmonics and high starting currents pollute electrical networks with dirty power that can make connected equipment behave erratically. In severe cases they can cause damage to sensitive electronic equipment and interference in communication equipment, and give false readings on measurement devices. In the case of the nearby dwellings, it was these harmonics that were responsible for interferences in their electrical lighting systems. Across summer months, when treated water consumption increases and the network demand is at its limit, the impact on the network was even greater.
It became Remtron’s goal to not only solve the network disturbances, but also assist the council in optimising its system’s overall infrastructure to reduce the risk of operational failure, extend equipment lifetime and increase energy efficiency — and therefore reduce carbon emissions and subsequent electricity costs.
Inefficiencies identified in the existing pumping system
Analysis of the existing soft starter and motor pumping system indicated efficiency gains can be realised by using variable speed drive control.
A more efficient method to pump water is by using variable flow control and operating at the pump’s best efficiency point (BEP). The BEP is found along the pumping curve by measuring water flow rate and pressure.
After installing a variable speed drive (VSD), it was observed that when operating at motor frequency 45 Hz water was pumping at 176 litres per second. As a comparison, when the motor frequency was increased to 50 Hz, water was pumping at a higher flow rate of 210 litres per second. Remtron determined that although that 50 Hz achieves a greater flow rate, because it’s not at the BEP, it costs significantly more to pump.
Tumblr media
AlburyCity Council’s pumping system interface, with pressure and flow rate indicators.
Tumblr media
Pumping chart shows the flow rate at 45 and 50 Hz, and the relative energy consumed in amps (A).
Technologies to solve the problem, easily
A drive and motor package was identified to be the best solution for AlburyCity Council. It featured ABB’s ACQ580 ultralow harmonic (ULH) variable speed drives (VSD) and ABB’s M2BAX IE3 premium efficiency motor.
ACQ580 water-dedicated drives are engineered to reduce harmonics in the power network. They easily integrate into the council’s existing system without concerns of wider disruption. This meant there was no need to oversize the electrical system or budget for broader investment in additional infrastructure. Also, by using this clean technology, the need for any additional filters or power quality equipment is eliminated.
Alternative 6-pulse drives emit 30–45% total harmonic distortion (THDi), compared to ULH drives which typically emit less than 3%. In contrast to other harmonic mitigation technology that use external filters, ACQ580 ULH drives are also much easier to install, with minimal wiring required thanks to their design and small footprint.
Tumblr media
ABB’s drive and motor package, installed in AlburyCity Council’s pump room.
Tumblr media
Installed ABB ACQ580 ULH variable speed drive onsite at the water pumping station operated by AlburyCity Council.
Tumblr media
Second ABB ACQ580 ULH drive installed in the pump room on site, used to optimise existing application as a customised approach by Remtron to give AlburyCity Council the best outcome. The control system also features ABB automation equipment including an ABB AC500 PLC and ABB CP610 HMI touch screen visual display unit for digitalised monitoring.
The ACQ580 drives improved the quality of the power network and enabled the system to advance from a fixed speed application to variable speed. The ULH drive ensured that THDi was less than 3%, even when the motor pump speed was varied.
“We knew we would be saving energy by knocking a couple of Hz off the speed of a motor by installing a VSD, but through this project we now understand how to choose the best motor speed and more importantly all of the other benefits achieved by installing a VSD,” said Mitch Palmer, Electrical Supervisor for Construction and Maintenance at AlburyCity.
AlburyCity Council now benefits from the efficiency delivered by variable speed motor control. It was proven that running at 50 Hz full speed results in pumping 1.03 litres per second per ampere; however, this was less efficient than running at 45 Hz, which results in higher efficiency pumping at 1.22 litres per second per ampere consumed.
By lowering the speed of the pump, the council benefits from better performance overall whilst lowering energy consumption. “It’s essentially optimising the demands of the process with less wear and tear, lower pump cavitation and hydraulic stress through the pipes, just by being able to reduce motor speed by 10% via the drive,” said Merrett.
“But first and foremost, it solves the original problem — there’s no more light flickering for any building in the area.”
ABB’s M2BAX low-voltage IE3 premium efficiency motors were also installed at the pumping station site. The motors, supplied by ABB Channel Partner A1 Electric Motors, are a cast iron motor especially designed for applications like pumping, because they’re robust even in tough, ambient conditions.
The electricity needed to power equipment like motors has long known to be the culprit of lofty operating costs. Premium, high-efficiency motors provide greater overall cost savings for users thanks to their low energy operational needs and long-term product life cycle. This also supports the reduction of environmental impact across the entire motor lifetime.
Results that exceed expectations
The newly upgraded system equipment has allowed the Council to run its pump at BEP. The council has already gained 20–30% in energy savings, which has resulted in reduced electricity running costs. During the starting of the pump there have been no disturbances to the power system.
The harmonics remain low during operation, exceeding Australian AS61000 standards guidelines, and the pump efficiency can now be matched to the system efficiency, slowing the pump to 45 Hz, to achieve greater overall energy efficiency.
In reflecting on the project work he undertook with ABB Channel Partners Remtron and A1 Electric Motors, Palmer said, “I had a somewhat thorough knowledge of motors and drives and, while I knew there was more to learn, these guys blew me away. I really enjoyed working alongside Remtron and A1 Motors. Not only did they share their knowledge of equipment solutions and all things electrical, their mechanical comprehension was invaluable. The effects mechanical and electrical components can have on one another when there is a problem is profound, but equally so when all factors have been considered and aligned. The results are genuinely impressive.
“Using energy efficient motors and ultralow harmonic drives, with the added benefit of unity power factor, has allowed us to capture cost savings in total power consumption.”
To learn more, read the full case study here.
Top image caption: (L to R) Anthony Merrett from Remtron and Mitchell Palmer from AlburyCity Council, beside ABB’s M2BAX IE3 high-efficiency motor.
source http://sustainabilitymatters.net.au/content/energy/article/advanced-pump-system-upgrade-cuts-alburycity-council-costs-82106565
from WordPress https://davidkent.home.blog/2021/03/31/advanced-pump-system-upgrade-cuts-alburycity-council-costs-2/
0 notes
eastgroup · 4 years ago
Text
East’s modular UPS serves data centers in Bolivia
Bolivia is a landlocked country located in western-central South America. It is well known by its rich minerals including tin, silver, lithium and copper in the world. In addition to the famous mineral deposits, there is a miracle and tourist resorts and archaeological resorts, that is, Inca Empire ruins.
The municipal construction of Bolivia has accelerated over the years. As a symbol of reliability, safety and efficiency, East UPS system contributes to the municipal construction of Bolivia. East modular UPS provides reliable protection for local commercial banks, the Supreme electoral court and 110 citizen security project. The data processing and storage of these key institutions is very important, and there must be no interruption for any power supply. Otherwise it will cause irreparable losses. East's UPS system not only provides reliable power protection for data processing and storage system, but also creates a purified application environment for the power supply of key equipment of these projects to ensure their life span.
There are 3 UPS projects installed in Bolivia in 2018 & 2019 respectively.
Tumblr media
▲Banco Mercantil Scz 3 x 200kva modular UPS
Tumblr media
▲Tribunal Supremo Electoral 2 x 200kva modular UPS
Tumblr media
▲Bol 110 Control de Seguridad Ciudadana 2 x 400Kva modular UPS
The UPS systems have been working very well since installed and commissioned one year ago. “The performance of UPS systems is stable and the maintenance is simple and convenient,” said the customer, “we appreciate EAST for the excellent product quality and strong technical support which makes us worry-free during the whole installation and commissioning.”
EAST's power supply systems constructed by Bolivia has become a model of collaborative cooperation under the framework of the “Belt and Road” initiative, with the principles of “co-consultation, co-construction and sharing”.
EA660 50 kVA ~ 800 kVA
Tumblr media
    Highlights
High power factor 1.0
High efficiency 96.5%
High adaptability
Power flexibility from 50 – 800 kW
Modular hot-swappable & Scalability
High MTBF and low MTTR
EA660 modular UPS is ideal for reliable, saving, intelligent and easy solutions. It ensures that a scalable, secure, high quality power supply is available for any critical high-density computer and IT environment applications, such as data centers and other critical loads.
EA660 modular UPS is a scalable three-phase / three-phase uninterruptible power supply system with DSP technology and provides true on-line double conversion power protection. The available UPS power and redundancy level can expand vertically from 50 to 800 kVA / 800 kW in one single power cabinet, and four power cabinets can be connected in parallel, increasing the capacity up to 3.2 M kW. It features modular hot-swappable design, all modules support “plug & play”, including power modules, bypass module, and control module, simplifies UPS servicing and maintenance.
Features:
Dual DSP digital control technology
Flexible modularity and easy scalability with all hot-swappable module design
High efficiency at low load rate: 96% at 40% rated load and 95% at 20% rated load
High power density of 50 kVA / 3U power module
Wide input voltage range, high grid adaptability, strong load adaptability and strong overload capability
Small footprint (500 kVA system only 1.02 m2 footprint)
Inbuilt integrated PDU system, easy installation and saving investment
Input power factor > 0.99, THDi < 3%, environment friendly and high-efficiency and energy-saving
Soft-start technology improves generator matching up to 1:1.1
Support two modes of frequency conversion: 50 Hz input / 60 Hz output and 60 Hz input / 50 Hz output
Intelligent hibernation design enables UPS to operate efficiently at low load rate to prolong service life and improve the system efficiency.
Advanced parallel expansion technology, support 4 units in parallel
Share battery pack in parallel operation, saving user’s battery cost
Flexible charger parameter and battery configuration setting, numbers of battery 30 ~  46 pcs selectable
Intelligent battery management (Intelligent charge/discharge management and float charging voltage temperature compensation), extending battery lifespan
Support battery cold start and utility self boot
Self-aging function, easy debugging and test on site
Fault-tolerant design for fan system: 30% load can be driven when 2 fans fail and 50% load when 1 fan fails
Front accessible maintenance,top/bottom cable entry compatible
Complete hardware and software protection function, robust self-diagnostic function, and abundant event log for check
7 inches LCD touch screen, friendly human-machine interface
Monitoring unit with built-in SNMP, supports RS485 and dry contacts
0 notes
sorotec · 6 years ago
Text
Introduction of Harmonic Filter
A device used to filter one or more harmonics in power system; most of its structures are composed of inductors, capacitors and resistors, i.e. passive harmonic filters, which also serve as reactive power compensation; the emerging filtering technology also includes active harmonic filters.
It is used to filter harmonics in power system with voltage less than 1000 volts, such as harmonics generated by six-pulse rectifier, also known as harmonic generator.
Based on the principle of electromagnetic induction and reactor, a filter compensation system is composed of high performance filter capacitors connected in series with high linearity filter devices to compensate reactive power while absorbing the main harmonic components of the system. By integrating dynamic reactive power compensation and filtering functions, it can quickly follow the load changes, and has three main functions: restraining current fluctuation, absorbing harmonics of power grid and compensating reactive power.
Three-phase Balance Active Harmonic Filter(AHF)
– PF=0.99 and THDi < 5% – Compensation for 2- to 50-order harmonics – Capacitive and inductive reactive power compensation – Three-phase unbalance co
Learn More
Tumblr media
0 notes
Text
The Future For Modular UPS Systems
Tumblr media
Costa Power Industries Pvt. Ltd. sells and performs services on all of the leading manufacturer’s modular ups systems. Costa have ample of experience with modular ups battery backup for control applications and harsh environments. Continuity of process control is critical across a vast range of industrial markets : Waste Water, Biotech, Pharmaceutical, Transportation, Chemical, Food & Beverage, Semiconductor, Automotive & Renewable Energy. modular online UPS systems are designed for environments with prevalent fluctuations in electric power supply, power interruptions and cuts. Costa Power is market leader for modular ups suppliers, modular ups dealers for standard brand i.e. APC UPS, Vertiv UPS, Numeric UPS, Hitachi UPS, Microtek UPS & Delta UPS.
Costa Power is topmost in offering Modular UPS System to our customers. It is next generation product. It consists of 1 to 10 UPS modules of 10kVA each, a system controller, static switch module, and distribution block and others. It can be easily upgraded from 10kVA to 100kVA and is made for hot insertion as well. In this product, inverter is used for supplying power to load and it takes power by usage of AC input.
Other details :-
Range :- 10 – 500 KVA Modular UPS
The rectifier is controlled to recharge the battery and maintain it in charged condition. The battery is galvanically connected between the rectifier output and the inverter input on a common DC link.
Features :-
Unity Input PF and THDi of 5%, Truly Green Power.
Truly modular :- 1 to10 Hot Swap Plug-in modules of each 10KVA capacity allowing Upgrading UPS capacity from 10KVA to 500KVA.
True Online Battery according to IEC 62040-3.
High Overall efficiency of 96% and 98% during backup mode.
Lower heat dissipation of 333W per 10KVA single module.
Flexible to configure as 3/3, 3/1 & 1/1 Input/output configurations.
Built-in Redundancy of N 1.
Intelligent battery test facility.
Unique light and compact design.
Large LCD display of 4×40 Character with 256 event logging facility.
Independent charging system for every module.
For More details –
Visit – www.upsbatteriesindia.com
Call – 9820710392 / 9372217661
0 notes
alliedindustrialmarketing · 3 years ago
Photo
Tumblr media
New Post has been published on https://www.alliedindustrialmarketing.com/mangoldts-harmonic-filter-kits/
Mangoldt's Harmonic Filter Kits - Finalist for the CSE Magazine
Mangoldt IHF Input Harmonic Filter Kit with Building Block Versatility!
Mangoldt’s Harmonic Filter Kits Please Vote! We are honored to inform you that Mangoldt’s Harmonic Filter Kits are a Finalist for the Consulting-Specifying Engineer Magazine “Product-of-the-Year-Award” in the Power Systems & Equipment category!
Voting is taking place now, and we would appreciate your help!
You can register and vote at: https://surveys.cfemedia.com/s3/votecse2021poy.
First Register at CSE magazine
Scroll down the page for category headings Heading: “Power Systems & Equipment”
Vote for Mangoldt Type IHF Kit. 
      The voting will end on September 10th, 2021, so we need your support.
We appreciate the recognition that Mangoldt’s IHF Harmonic Filter Kits are getting for their building blocks versatility and guaranteed harmonic distortion levels of 5%, 8% or 12% THD-i, with lower-cost options for VFDs with internal reactors.
In June, we were excited to debut our Input Harmonic Filter (IHF) kits at the EASA 2021 Convention in Fort Worth, Texas.  The IHF Filter Kits were well received by OEMs and System integrators alike.
Please check out the IHF Harmonic Filter Kits for yourself. Our VFD Input Harmonic Filters can achieve 5%, 8%, or 12% THDi in VFD applications and may also be used with DC drives and other 6-pulse AC to DC rectifiers.  Mangoldt IHF Harmonic Filter Kits are an excellent way for you to offer harmonic mitigation to broaden your product portfolio.
Did we mention the IHF Harmonic Filter Kits are affordable too?
Check us out today!  Here is a link to the Catalog & Selection Chart.  
IHF Input Harmonic Filter page
We strive to make a difference by partnering with our customers to protect electrical assets and production equipment. We look forward to hearing from you!
0 notes
alliedindustrialmarketing · 4 years ago
Photo
Tumblr media
New Post has been published on https://www.alliedindustrialmarketing.com/mangoldt-adds-3-new-filter-product-lines/
Mangoldt Adds 3 New Filter Product Lines
May 15, 2021
Mangoldt Filter Line
  FOR IMMEDIATE RELEASE
  New Sine Wave Filter / L-C-L Filter Kits & Harmonic Filter Kits offer high performance and flexibility
  Mangoldt Adds 3 New Filter Product Lines. Mangoldt’s new line of CUL Listed PolyGap® Sine Wave Filters / L-C-L Filters, and VFD Input Harmonic Filters are available for use at up to 690V, 50 or 600V, 60 Hz. 
Press release:
Hans von Mangoldt introduces PolyGap® Sinewave Filters / L-C-L Filters & Input Harmonic Filters.
Mangoldt, working from many decades of experience and capitalizing on leading edge manufacturing technology, launches two new product lines. The PolyGap® Sine Wave Filter / L-C-L Filters, and the VFD Input Harmonic Filter kits utilize Mangoldt’s popular PolyGap®  core reactors for high performance, low power loss solutions to difficult power quality problems.
The new PolyGap® Sinewave Filter and VFD Input Harmonic Filter kits offer OEMs, integrators, engineering companies, and electrical contractors the high quality and flexibility needed to achieve exceptional power quality for AC or DC drive systems.  PolyGap® L-C-L filters are for active front end inverters as used for renewable energy systems, DC battery storage systems and VFDs with active front ends. We can even offer the products with liquid cooled reactors.  Our VFD Input Harmonic Filters can achieve 5%, 8% or 12% THDi and may also be used with DC drives and other 6-pulse AC to DC rectifiers. Selection can be based on whether or not the VFD has an internal reactor and is dependent on what level of harmonic current distortion you wish to achieve (5%, 8% or 12% THD-i).
Mangoldt’s in-depth experience with renewable energy, energy storage, oil & gas, power factor correction, grid-tied inverters plus HVAC and water industries has fueled our endeavor to offer the highest level of system power quality for electrical systems. Our reactors, both medium and low voltage as well as both air and liquid cooled, can be found in applications throughout the world.
Every Mangoldt reactor is fully tested and serialized and has a test report available. Our reactors have been UL Tested in real-world conditions including full harmonic currents and have built Mangoldt’s reputation for high quality and high reliability with many decades of operation in power factor and harmonic filter system applications. Filtered drive systems improve the quality of the power system voltage and enable electrical /electronic equipment to operate more effectively, efficiently and to last longer. The very reason to use a filter in the first place!
  Technical Support Office and for more information contact:
John Houdek
Allied Industrial Marketing, Inc                
W67 N222 Evergreen Blvd., Suite 209
Cedarburg, WI 53012
Phone: 262-618-2403
Fax: 262-618-2303
Please visit our site for product brochures, technical papers and watts loss data.
www.AlliedIndustrialMarketing.com
Mangoldt Line of Reactors and Filters are stocked in both USA and Canada.
Direct sales through stocking partner:
PQ Components USA  email: [email protected]
PQMC Canada  email: [email protected] 
World Headquarters: www.mangoldt.com
Mangoldt Filter Line
  Encl: Product photo
          # # # 
0 notes
alliedindustrialmarketing · 4 years ago
Photo
Tumblr media
New Post has been published on https://www.alliedindustrialmarketing.com/mangoldt-adds-3-new-filter-product-lines/
Mangoldt Adds 3 New Filter Product Lines
May 15, 2021
Mangoldt Filter Line
  FOR IMMEDIATE RELEASE
  New Sine Wave Filter / L-C-L Filter Kits & Harmonic Filter Kits offer high performance and flexibility
  Mangoldt Adds 3 New Filter Product Lines. Mangoldt’s new line of CUL Listed PolyGap® Sine Wave Filters / L-C-L Filters, and VFD Input Harmonic Filters are available for use at up to 690V, 50 or 600V, 60 Hz. 
Press release:
Hans von Mangoldt introduces PolyGap® Sinewave Filters / L-C-L Filters & Input Harmonic Filters.
Mangoldt, working from many decades of experience and capitalizing on leading edge manufacturing technology, launches two new product lines. The PolyGap® Sine Wave Filter / L-C-L Filters, and the VFD Input Harmonic Filter kits utilize Mangoldt’s popular PolyGap®  core reactors for high performance, low power loss solutions to difficult power quality problems.
The new PolyGap® Sinewave Filter and VFD Input Harmonic Filter kits offer OEMs, integrators, engineering companies, and electrical contractors the high quality and flexibility needed to achieve exceptional power quality for AC or DC drive systems.  PolyGap® L-C-L filters are for active front end inverters as used for renewable energy systems, DC battery storage systems and VFDs with active front ends. We can even offer the products with liquid cooled reactors.  Our VFD Input Harmonic Filters can achieve 5%, 8% or 12% THDi and may also be used with DC drives and other 6-pulse AC to DC rectifiers. Selection can be based on whether or not the VFD has an internal reactor and is dependent on what level of harmonic current distortion you wish to achieve (5%, 8% or 12% THD-i).
Mangoldt’s in-depth experience with renewable energy, energy storage, oil & gas, power factor correction, grid-tied inverters plus HVAC and water industries has fueled our endeavor to offer the highest level of system power quality for electrical systems. Our reactors, both medium and low voltage as well as both air and liquid cooled, can be found in applications throughout the world.
Every Mangoldt reactor is fully tested and serialized and has a test report available. Our reactors have been UL Tested in real-world conditions including full harmonic currents and have built Mangoldt’s reputation for high quality and high reliability with many decades of operation in power factor and harmonic filter system applications. Filtered drive systems improve the quality of the power system voltage and enable electrical /electronic equipment to operate more effectively, efficiently and to last longer. The very reason to use a filter in the first place!
  Technical Support Office and for more information contact:
John Houdek
Allied Industrial Marketing, Inc                
W67 N222 Evergreen Blvd., Suite 209
Cedarburg, WI 53012
Phone: 262-618-2403
Fax: 262-618-2303
Please visit our site for product brochures, technical papers and watts loss data.
www.AlliedIndustrialMarketing.com
Mangoldt Line of Reactors and Filters are stocked in both USA and Canada.
Direct sales through stocking partner:
PQ Components USA  email: [email protected]
PQMC Canada  email: [email protected] 
World Headquarters: www.mangoldt.com
Mangoldt Filter Line
  Encl: Product photo
          # # # 
0 notes
daisyliu618 · 4 years ago
Photo
Tumblr media
When we talked about this DT series 3/3 phase IGBT rectifier & IGBT inverter model with THDI<4% and overall efficiency is up to 93%,these parameter seems common in the catalog we see today. but when we show the price, we often got an reply why yours is much too high? So until we send a sample for testing, and take a look of internal, they understand. we'd like to testify that what we show on the catalog is what we can really meet, there are various area required an reliable & efficiency equipments. DT it is a transformer-less UPS, while we use 12pcs inductor here, full IGBT module in R,S,T phase, 90% system components are from international brands, every materials counts. The catalog may lie, while the test result never. #Jeidar #kotohirasystem #ups https://www.instagram.com/p/CMzYtxYjs44/?igshid=1hnz567fc2rbb
0 notes
sorotec · 5 years ago
Text
Matching between Generator Set and UPS
Manufacturers and users of UPS power supply system have long noticed the matching problem between generators and UPS, especially the harmful effects of current harmonics generated by rectifiers on power supply systems such as voltage regulators of generators and synchronous circuits of UPS. Therefore, the technicians designed the input filter and applied it to UPS, and successfully controlled the current harmonics in UPS application. These filters play a key role in UPS compatibility with generators.
In fact, all input filters use capacitors and inductors to absorb the destructive current harmonics at the UPS input. The design of the input filter takes into account the percentage of all possible harmonic distortion inherent in the UPS circuit and at full load. Another benefit of most filters is to increase the input power factor of UPS with load. However, another consequence of the application of input filters is to reduce the overall efficiency of UPS. Most filters consume about 1% UPS power. The design of input filters has been seeking a balance between advantages and disadvantages.
In order to improve the efficiency of UPS system as much as possible, UPS engineers have recently improved the power consumption of input filters. The improvement of filter efficiency depends largely on the application of IGBT (Insulated Gate Transistor) technology to UPS design. The high efficiency of IGBT inverters leads to the redesign of UPS. The input filter can absorb some current harmonics and a small part of active power. In short, the ratio of inductance factor to capacitance factor in the filter is reduced, and the volume of UPS is reduced and the efficiency is improved. The compatibility between UPS and generators is another problem.
MPS9335C 10-300KVA High Frequency Online Modular Type UPS
1.Superior energy saving and environment-friendly: Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%. 2. Superior capability of powering load: Output PF is 0.9 or 1, no need of power deration with load of leading or lagging PF. 3. Easy-to-install: Top or bottom cabling, no need of input cabling cabinet. 4. Easy-to-maintain: Full front access, UPS, failed part can be replaced shortly. 5. Easy-to-modify: The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS. 6.6-inch extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanlish and so on). 7.Provide large LCD touch screen (optional). 8.Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A. 9.On-Line Double Conversion, fully isolating the influences of power grid pollution and power failure from utility power supply and diesel generator to load. 10. Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance. 11.Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet. 12.Digital load sharing technology features extra low cross current and extreme high system reliability in parallel operation. 13.Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges. 14.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety at limit conditions. 15 Intelligent battery management maintains battery automatically to prolong the battery life. 16. Efficient heat dissipation and effective protection under severe environment due to its independent layer-sealed ventilation channel and redundant fan design, as well as the paint-protected circuit boards and built-in dust filter. 17.Applicable voltage south America.
Learn More
0 notes
sorotec · 5 years ago
Text
Why do people like to talk about power quality nowadays
Nowadays, many people like to talk about “power quality”. There are many products of power quality, such as SVG, APFand three-phase unbalanced regulator, which have become “hot-selling products”. But what are the benefits of improving power quality for people?
Improving power quality is of great significance to the safe and economic operation of power grid, ensuring the quality of industrial products and the normal conduct of scientific experiments, and reducing energy consumption. Power quality is directly related to the overall benefits of the national economy. Good power quality is undoubtedly beneficial to the operation of electrical equipment, but the adverse impact of poor power quality on the operation of power system has not attracted enough attention. From the point of view of harm degree, the harm of some power quality problems is destructive. For example, the overvoltage caused by harmonic resonance in lightning impulse, capacitor and cable switching often causes insulation and mechanical damage of electrical equipment, thus affecting the normal operation of power system. The misoperation of relay protection device caused by harmonic and negative sequence interference will cause huge economic losses in large-scale blackout of power grid. Short-term power supply interruption or voltage drop may lead to production chaos or a large number of industrial smelting products scrapped or even endanger personal safety. On the other hand, some power quality problems mainly affect the performance indicators of electrical equipment. For example, abnormal voltage and frequency deviation will cause the change of speed and power of asynchronous motor load, which will reduce the efficiency of transmission machinery and affect the quality of textiles, papermaking and other products. Harmonic currents circulate in transmission and distribution equipment such as rotating motors, transmission lines and transformers, which overheat these equipment due to additional losses, thus reducing the life or capacity of these equipment. However, it can not be explained that the former power quality problem is more important than the latter. The actual situation is that the latter power quality problem, due to the wide range of electrical equipment involved, has the same impact as the former power quality problem.
There have been a lot of achievements on the study of the harm of deterioration of power quality indicators to electrical equipment. However, different indicators of power quality have different effects on different equipment. Especially when there are multiple indicators of power quality, the impact of different combinations on equipment is a very complex problem. At present, there is no accurate quantitative formula, only some rough formulas and conclusions. The results can be used for engineering estimation.
Therefore, in general, the closer the power quality index is to the rated value, while ensuring continuous and reliable power supply is the symbol of high quality of power. However, from production to consumption of electric energy is an integral whole. The generation, supply and use of electric power system are always in a dynamic balance, and any link of it will have an impact on the quality of electric power. The control of power index needs considerable investment (including the improvement of power grid structure, the balance of active power and reactive power, the use of various frequency modulation, voltage regulation, filtering and reactive power compensation devices, as well as the technical management of dispatching and operation), and the control technology of various index is constantly developing and improving. In fact, the deviation between the power quality index and the rated value is inevitable. The task of formulating power quality standards is to determine the appropriate allowable deviation of power quality indicators from the current (or recent) technical level.
The criteria for judging whether the criteria are reasonable or not should be: 1.Basically, it can ensure the security, continuous power supply and economic operation of the power system. 2.On the whole, it can ensure the normal use of electricity for users’electrical equipment. 3.On the basis of the current technological level, the power sector (including interfering users) should be able to meet the standards after making certain efforts.
400V/480V/690V Static Var Generator(SVG)
Meeting users’ requirements: -COSφ=1.00 -Capacitive and inductive reactive power compensation -Three-phase unbalance compensation
Learn More
Tumblr media
Three-phase Balance Active Harmonic Filter(AHF)
Meeting users’ requirements: – PF=0.99 and THDi < 5% – Compensation for 2- to 50-order harmonics – Capacitive and inductive reactive power compensation – Three-phase unbalance co
Learn More
Tumblr media
0 notes
sorotec · 6 years ago
Text
How to select harmonic filters
1.Based on the rated current of the final electric load (motor), it is better that the rated current of the harmonic filter is more than 1.1 times of that of the load current. 2.Look at the rated working current and actual working current of the load, and do not exceed the rated working current of the harmonic filter. 3.Look at the load rate. If the load rate is too low, it will affect the effect of harmonic filter. Please check load rate data when selecting the type. 4.Check the rated working voltage and power frequency of the load equipment to see if it meets the power requirements of the harmonic filter. 5.Attention should be paid to the installation environment of harmonic filters, which meets the requirements of the environment for the use of harmonic filters. 6.It is better to provide the power factor of the load so that suitable capacitors can be installed to achieve the best power factor.
SOROTEC Three-phase Balance Active Harmonic Filter (AHF)
Meeting users’ requirements: – PF=0.99 and THDi < 5% – Compensation for 2- to 50-order harmonics – Capacitive and inductive reactive power compensation – Three-phase unbalance co