how to manage hospital waste
Incinerator Equipment Performance Requirements The principal activities of the Contract are the supply, install, commissioning and operations training. The required standards for the Contract activities are set out in the following Scope of Works below. The required minimum performance criteria for the incinerator to be provided by the bidder(s) is set out in this section. General: The proposed…
View On WordPress
3 notes
·
View notes
Text
TECHNICAL SPECIFICATIONS FOR INCINERATOR– 50 KGS/HR
1. Brand Type & Model,Indicate •Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The majority of the wastes will be of bio medical nature, with up to 70% by volume of medical wastes and up to 30% by volume of hazardous and or general wastes. The content of the combustible matter will be above 60% and moisture content below 35%. The…
View On WordPress
2 notes
·
View notes
Text
PLC based control box for incinerator
i. Circular Mild Steel / Stainless steel with minimum thickness 3mm, self-supported flange section chimney and should have suitable door/window at the base for cleaning. ii. Proper port for taking exhaust gases sample to monitor emission levels as per international standards provided with a cover to be opened and closed when needed without affecting the function of chimney. iii. Chimney should…
View On WordPress
2 notes
·
View notes
Text
HOSPITAL WASTE INCINERATOR incineration Secondary Chamberincineration Secondary Chamber
According to the European Waste Incineration Directive, incineration Secondary Chambermust be designed to ensure that the flue gases reach a temperature of at least 1100 °C for 2 seconds in order to ensure proper breakdown of toxic organic substances. ii. Blower Centrifugal fan (according to manufacturer design) will be provided to inject air for burning waste and gases in Secondary combustion…
View On WordPress
0 notes
Text
Medical Waste Incineration and Medical Incinerators
1.BurningCapacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2.Construction i. Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non- cracking refractory bricks…
View On WordPress
0 notes
Text
HOSPITAL WASTE INCINERATOR hospital waste management system
Incinerator (hospital waste management system) is a turn-key project which will comprise a hospital grade incinerator, allied accessories and operation for proper disposal of hospital General medical waste (plastics, gloves and papers) and Infectious waste (blood-soaked bandages, sharps waste, surgical waste, human or body parts, cultures, and swabs).the unit should be of high performance to…
View On WordPress
0 notes
Text
discuss the design and operation or various types of incinerators
The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid) All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices…
View On WordPress
0 notes
Text
clinical waste treatment 5kgs 10kgs 20kgs and 30kgs per hour average
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion The incinerator combustion chamber(s) should…
View On WordPress
0 notes
Text
HICLOVER Mobile Containerized Incinerators
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components. b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions. d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated. e. achieve a Total Organic Carbon (TOC) content in the slag…
View On WordPress
0 notes
Text
DOMESTIC INCINERATOR, YD 300 Spare Parts for Waste Incinerators and Burners
incineradores de residuos para fabricantes de uso general y municipal en paraguay concept of incinerator machine Ceramic filter candle 1mtr Filter-Candle Sick sensor encoder BCG13-L1KM05PP LID REPAIR KIT I8-1000 I8-1000 Lid Repair Kit SS Chimney SS Chimney SS Chimney extension SS Chimney extension SS Chimney Cowl SS Chimney Cowl Refractory cement CA50-A600 Asbestos…
View On WordPress
0 notes
Text
Containerized Mobile Incinerator
Containerized Mobile Incinerator͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ …
View On WordPress
0 notes
Text
Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower
View On WordPress
0 notes
Text
large scale incinerator
Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:6.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 04 sets Oil Tank (if oil fuel): 800Liters The secondary chamber must comply with the following minimum criteria: “• Heavy steel construction small scale incinerators incinerator burner • An excess air and high…
View On WordPress
0 notes
Text
double chamber incinerator
Nanjing Clover Medical Technology Co.,Ltd. • Also consider provision for meeting international emission standards. Able to handle an average waste production of 100kg/day “• Minimum load capacity: 20 kg • Maximum load capacity: 40 kg • Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day) The proposed incinerator units must be complete and include all of the key features listed…
View On WordPress
0 notes
Text
General waste incinerator with automated feeding system
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components. b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions. solid waste incinerator for medical waste disposal china incinerators Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity…
View On WordPress
0 notes
Text
Industrial hazardous and nonhazardous waste and medical infectious waste
Industrial hazardous and nonhazardous waste and medical infectious waste Incinerator Items/Model HICLOVER TS500(PLC) HICLOVER TS300(PLC) Burn Rate (Average) 500-600 kg/hour 300-500 kg/hour Feed Capacity(Average) 600kg/feeding 400kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 3000Liters(3.0m3) 2000Liters(2.0m3) Internal…
View On WordPress
0 notes
Text
industrial waste incinerator
Items/Model TS2000 (Top Feeding) Principle Waste Incineration Treatment Burn Rate Average 500-600kg/hour Feed Capacity Average 4500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 7700Liter (7.7m3) Internal Dimensions 5000*1400*1100 mm Secondary Chamber 4000Liter (4.0m3) Feed Mode Manual/Forklift/Crane Description Brand Model Fuel Type Waste…